Description
Key Technical Specifications
| Parameter | Specification |
|---|---|
| Power Supply | 24 VDC (18 – 36 V) |
| Power Consumption | 12 W |
| Load Cell Inputs | 4 channels (Pressductor) |
| Load Cell Excitation | 0.5 A rms, 330 Hz |
| Max Cable Resistance | 10 Ω (4 load cells + 10 Ω) |
| Analog Outputs | 6 (configurable voltage or current) |
| Analog Inputs | 2 (for multi-unit cascading) |
| Digital Inputs | 1 (remote zero or gain scheduling) |
| Communication | PROFIBUS-DP (GSD: ABB_0717.GSD) |
| Display | 2×16 character multi-language |
| Mounting | DIN-rail (IP20) |
| Operating Temp | +5°C to +55°C |
Product Introduction
You don’t buy a PFEA113-20 for a simple rewind stand. You buy it when you have a multi-span web line, four load cells, and a process engineer breathing down your neck about coating uniformity. This is the top-dog module in ABB’s PFEA11x lineup. It takes the raw mV/V signals from up to four Pressductor load cells, does the math, and spits out clean, filtered tension data to your PLC or drives.Why do I like it? The cascading feature. You can link up to three of these units via the analog inputs to monitor a massive 12-span section. The 330 Hz excitation frequency is fast enough to catch transient tension spikes before your web snaps. Just a heads-up: the IP20 DIN-rail version is strictly for the control cabinet. If your plant floor looks like a dust storm, keep it behind glass or step up to the IP65 PFEA113-65.
Quality SOP & Tech Pitfalls
The Lab Report (SOP)
Nothing leaves my bench without a fight.
- Visual inspection. I’m checking for shipping damage, bent DIN clips, and counterfeit label fonts.
- Bench power-up with a Fluke 87V. I verify the 24 VDC input draws the correct 12 W.
- Load cell simulator test. I inject a known mV/V signal into all four channels and verify the display matches within 0.1%.
- PROFIBUS-DP handshake. I connect it to a test PLC using the ABB_0717.GSD file to ensure the data exchange maps correctly.
- Anti-static bagging. ESD destroys these analog front-ends instantly.
The Engineer’s Warning (Pitfalls)
The number one killer of these modules is improper grounding. The metal base of the PFEA113-20 must make solid contact with a grounded metal DIN rail. I’ve seen techs mount these on plastic standoffs or paint over the rail. The 330 Hz excitation acts like an antenna. Without a solid PE ground, you get induced noise that makes your tension readings jitter, and your PID loop will chase ghosts.Another trap? The analog output loading. The voltage outputs max out at 5 mA. If you wire them to a high-impedance device or daisy-chain too many inputs, the signal sags. Your PLC reads low tension, the drive speeds up, and you snap the web. Check your input impedance before wiring.
Installation & Configuration Guide
Phase 1: Pre-Installation
⚠️ Lockout the 24 VDC supply.
Photograph the existing terminal block. The Ex A/B (excitation) and In A/B (signal) wiring for four load cells is a nightmare to trace if you lose it. Note the PROFIBUS node address on the old unit.Phase 2: Removal
Label every wire. Use proper wire markers, not sharpie on electrical tape.
Release the DIN rail clips. Pull the module straight off the rail. Don’t pry against the PCB.Phase 3: Installation
Mount the new PFEA113-20 on the DIN rail. Ensure the metal base is biting through any paint or oxide to ground the module. This is non-negotiable.
Torque the PE ground screw to spec.
Reconnect the 24 VDC, load cell wiring, and PROFIBUS drop cable. Keep the analog signal wires twisted, shielded, and routed away from VFD power cables.Phase 4: Power-On & Testing
Apply 24 VDC. The 2×16 display should light up.
Check the PROFIBUS status. If it’s flashing, verify the node address matches the old module.
Go into the interactive menu. Perform a zero calibration with no web tension applied.
Apply a known test load. Verify the sum and difference readings on the display.
Check the analog outputs with a multimeter. Ensure they scale linearly with the applied load.
Compatible Replacement Models
- ✅ Drop-in Replacement: PFEA113-20 (Same material number). 100% hardware and firmware match. Just copy the PROFIBUS address.
- ⚠️ Software Compatible: PFEA113-65 (IP65 version). Same internal electronics, but sealed enclosure. Requires different mounting hardware and physical space in the panel.
- ❌ Hardware Mod Required: PFEA112-20. Only supports 2 load cells and lacks the analog inputs for cascading. You’d have to rewire half the load cells and lose multi-span capability.
- ❌ Hardware Mod Required: PFEA122. Uses PROFINET/EtherNet/IP instead of PROFIBUS-DP. Requires a complete network reconfiguration and new GSDML files in the PLC.
Frequently Asked Questions (FAQ)
Can I hot-swap this module?
Technically, yes, if your 24 VDC supply and PROFIBUS network support it. But I don’t recommend it. Pulling the module drops the analog outputs and breaks the PROFIBUS connection. Your PLC will see a fault and likely trip the line. Swap it during a planned stop.What happens if I exceed the 10 Ω cable resistance?
The 330 Hz excitation voltage will drop before it reaches the load cells. Your tension readings will read low, and the control loop will overcompensate. If your cable run is long, you need to upsize the wire gauge to keep the loop resistance under 10 Ω.Can I use third-party strain gauge load cells?
The PFEA113-20 is tuned for ABB Pressductor load cells. You can use third-party mV/V strain gauges, but you must carefully match the excitation voltage, input impedance, and bridge resistance. Verify the OEM datasheet for exact bridge specifications before wiring.How do I cascade multiple PFEA113-20 units?
You use the 2 analog inputs. You wire the analog output of the upstream unit into the analog input of the downstream unit. This allows the system to sum the tension across multiple spans. You’ll need to configure the scaling in the menu so the units talk the same language.Why is my tension reading jittering even with no web load?
Check your ground. 9 times out of 10, the DIN rail isn’t properly bonded to the cabinet PE. Also, check your filter time settings. The module offers 5 to 1500 ms filtering. If it’s set too low for your line speed, mechanical vibration will bleed into the signal.Does it come with the PROFIBUS GSD file?
The module doesn’t store the GSD file; your PLC does. You need to ensure the ABB_0717.GSD file is loaded into your PLC’s hardware catalog. If you’re replacing an old unit, the file should already be there. Just match the node address.