Key Technical Specifications
| Parameter | Specification |
|---|---|
| Part Number | MVAW11B1AB9007A |
| Manufacturer | ALSTOM (GEC-Alstom / later GE branding) |
| Function | Single-phase AC overcurrent protection |
| Rated Current | Configuration dependent — typically 1 A or 5 A CT secondary |
| Pickup Setting | Adjustable, range depends on specific variant |
| Time Characteristic | IDMT (inverse definite minimum time) or DTL (definite time), per configuration |
| Auxiliary Supply | Typically 24–250 VAC/DC |
| Outputs | At least one trip contact; NO or NC selectable |
| Contact Duty | Rated to drive a small breaker or interposing relay |
| Mounting | Panel or DIN rail |
| Operating Temperature | -25 to +55 °C (typical) |
| Insulation | To relevant IEC 60255 class |
Product Introduction
A substation in a steel mill tripped its feeder breaker at 3 a.m. on a Saturday. Not because of a fault — because the overcurrent relay’s pickup had drifted and its auxiliary supply sagged when the DC battery aged. Nobody had a spare. The line sat for eleven hours.That’s the MVAW11B1AB9007A‘s world. It’s an ALSTOM-era single-phase AC overcurrent relay from the MVAW11 series, built to watch one current circuit and open a contact when that current exceeds what you told it to tolerate. No display, no comms, no firmware to argue with. You set the pickup, you set the time curve, you close the door.Engineers don’t select this relay today — they inherit it in switchgear that’s still running fine. Its value is that it still exists as surplus. Pickup is adjustable, time characteristic is IDMT or DTL depending on the variant, and the auxiliary supply covers a wide 24–250 VAC/DC band. Subjective note: the -9007A suffix variants are picky about CT burden. Exceed the rated burden and the pickup point shifts. Measure the actual CT loop impedance before you energize.
Quality SOP & Tech Pitfalls
The Lab ReportSame five steps, every unit, before it gets boxed:
- Visual / counterfeit check — nameplate legibility, revision, PCB and capacitor inspection. Refurbished stock gets rejected here.
- Live pickup test — CT primary injected from a test set; pickup verified against the nameplate setting, trip contact confirmed to close.
- Timing check — IDMT curve spot-checked at 2x and 10x pickup, or DTL delay verified with a stopwatch and injection set.
- Electrical checks — Fluke 115 on the auxiliary supply, insulation resistance, contact continuity and contact resistance.
- Configuration logging + anti-static sealing — pickup setting, time dial, auxiliary voltage, and CT rating recorded on the packing slip. ESD bag, foam, desiccant.
Test report and video available on request. Ask for them.The Engineer’s WarningTwo mistakes dominate the failures I’ve seen.First: buying the wrong variant. “MVAW11” is a series. The suffix defines the pickup range, the time characteristic, and the auxiliary voltage. Order on the part number alone and you may get a DTL unit when your protection study requires IDMT — or a 24 VDC auxiliary when your panel runs 125 VDC. I’ve seen a relay arrive, get installed, and simply never trip. It wasn’t defective. It was the wrong curve.Second: not photographing the settings. Pickup dial, time dial, and any links or jumpers live on the old unit. Remove it without a photo and you’re guessing. A 0.2 second error on the time dial is the difference between a coordinated trip and a cascaded blackout.Field disaster, real: a plant replaced a failed relay with a “same series” unit from a reseller listing. Wrong auxiliary voltage. The relay energized, the coil drew current it wasn’t rated for, and the DC supply browned out. Two hours to diagnose, and the requisition had to be redone.
Installation & Configuration Guide
Phase 1 — Pre-Installation
- ⚠️ Open the CT secondary and short it before disconnecting. Never leave a live CT secondary open. That’s a voltage hazard and a destroyed CT.
- ⚠️ Take the feeder out of service. Confirm the breaker is open, racked out, and grounded per your LOTO procedure.
- ⚠️ Photograph everything. Pickup dial, time dial, links/jumpers, terminal wiring, nameplate, and panel cutout orientation.
- ⚠️ Record the settings from your protection coordination study, not just from the old relay.
Phase 2 — Removal
- Label CT and auxiliary wiring. Do not rely on memory or on the old labels.
- Short the CT secondary at the terminal block before unfastening.
- Release the panel mounting hardware. Pull the relay straight out.
Phase 3 — Installation
- Set pickup, time dial, and links to match your photos and your coordination study. This one step prevents most startup failures.
- Mount the relay in the cutout. Do not over-torque the panel clamps — the bezel cracks.
- Land CT and auxiliary wiring. Torque terminals to spec and pull-test each conductor.
- Remove the CT short only after the relay is fully landed.
Phase 4 — Power-On & Testing
- Energize the auxiliary supply. Verify rated voltage at the relay terminals with a multimeter.
- Confirm no alarm/trip LED is latched.
- Inject secondary current at 1.05x and 0.95x pickup. Verify trip and no-trip respectively.
- Verify trip timing against your coordination study.
- Close the breaker. Log the settings, injection results, and relay revision in your maintenance record.
Compatible Replacement Models
| Tier | Model | Notes |
|---|---|---|
| ✅ Drop-in | MVAW11B1AB9007A (any brand marking: GEC-Alstom / Alstom / GE) | Same part number across label generations. Verify suffix, pickup range, and auxiliary voltage. |
| ⚠️ Software/Setting Compatible | Other MVAW11 suffix variants (e.g., different pickup range or DTL vs. IDMT) | Same form factor and panel cutout. Requires full re-setting and re-testing; budget 4–8 hours plus a coordination check. |
| ❌ Hardware Mod Required | Modern static relays (SEL, Schneider MiCOM, ABB REF/REX, GE UR series) | Different cutout, different CT burden, different settings language. Only worth it for a planned switchgear upgrade. |
Frequently Asked Questions
Is this actually in stock, or will I wait three weeks?
Honest answer: it’s a discontinued ALSTOM-era part. Many sellers claim “in stock” while sourcing after you order. We check inventory before quoting. On the shelf, you get a lead time. Not on the shelf, you get a sourcing window instead of a lie.Can I hot-swap this relay?
No. Open the CT secondary and short it, take the feeder out of service, then swap. Hot-swapping a protection relay leaves an unprotectioned feeder and risks an open CT secondary.Will I lose my settings when I change the relay?
Yes, if you don’t photograph them. Pickup dial, time dial, and links live on the old unit. No photo, no settings.The reseller listing says it has RS485 and 4-20 mA outputs. Is that right?
No. That description belongs to a different product template. This is a single-phase AC overcurrent relay with a trip contact output. If your requisition mentions comms or analog outputs, stop and re-spec.My new relay won’t trip during the injection test. Is it defective?
Usually not. Check in this order: auxiliary supply voltage, pickup dial setting, CT polarity and burden, then the time dial. Nine times out of ten it’s the pickup dial or an open CT short still in place.What if I can’t source this part anymore?
Three options: obsolete-parts channel, a compatible MVAW11 variant with full re-setting, or a modern static relay with panel modification. For a protection function, hold a spare. It’s the cheapest insurance in the plant.What’s the warranty, and who pays if it fails?
12 months from delivery. Non-human-caused failure inside that window gets replaced. We ship injection test data with the unit, so if something goes wrong we compare numbers instead of arguing.