Key Technical Specifications
| Parameter | Value |
|---|---|
| Manufacturer | Bosch Rexroth |
| Type Designation | NYM04.1-MCUETHER-NY4112 |
| Product Type | Motion Control Unit (MCU) |
| Platform | NYM04.1 / Rexroth NY-series |
| Communication | Ethernet-based fieldbus interface |
| Function | Motion control, logic processing, system communication |
| Mounting | Panel / DIN-rail in control cabinet |
| Protection Rating | IP20 (indoor cabinet) |
| Origin | Germany |
| Condition | New Surplus |
| Status | Verify current availability with OEM — legacy NY-series platform |
Product Introduction
Rexroth’s NY-series platforms fail in a specific way: the power stage keeps running, the hydraulics keep moving, and the control card stops talking. NYM04..1-MCUETHER-NY4112 is the card that usually takes the hit — it runs motion and logic tasks and carries everything over an Ethernet fieldbus.Engineers stock these because NY-series machines are still running in press lines, injection molding, and mobile-hydraulic test stands worldwide, and the platform isn’t being built anymore. The spec I actually care about: Ethernet-based communication, which means you can diagnose it from a laptop instead of guessing at terminals. My honest note — the suffix matters enormously. NY4110, NY4114, and NY4112 are different variants. A seller who quotes “NYM04.1-MCU” without the suffix is guessing.
Quality SOP & Tech Pitfalls
The Lab Report
Five steps, every unit. Visual and counterfeit check — solder joints, connector plating, silkscreen, label print, and the Rexroth MNR barcode. Live power-up on a test rack; confirm the LED boot sequence. Insulation resistance and continuity with a Fluke 115 and a megger. Firmware and hardware revision photographed and logged. Anti-static bag, foam, sealed box.The Engineer’s Warning
One mistake dominates: buying the wrong suffix.I worked a job where a plant ordered “NYM04.1-MCU” from a listing, got an NY4110, and installed it in an NY4114 slot. Powered up clean. No alarms. Then the fieldbus refused to bind to the master, and the press line sat for four days while they chased a “communication fault.” The old card’s label had the suffix in plain sight. Nobody photographed it.Second issue: nobody backs up the parameter set before the swap. Rexroth MCUs hold motion profiles that are painful to rebuild by hand.
Installation & Configuration Guide
1. Pre-Installation ⚠️
Place the machine in a safe state — axes stopped, hydraulic pressure relieved. De-energize the control cabinet and wait for DC bus discharge; verify with a meter. Photograph the old card’s label (full suffix and MNR), jumper block, and every cable position.2. Removal
Label each cable and Ethernet connector. Release the mounting clips evenly; don’t pry one side and flex the card. Pull straight out.3. Installation
Confirm the new card’s suffix matches the old one exactly before insertion. Copy jumper and DIP settings from your photos. Seat fully until the connector engages and clips lock.4. Power-On & Testing
Verify 24 V DC at the card. Watch the LED boot sequence against the OEM manual. Restore the parameter set, confirm the fieldbus binds to the master, then run a low-speed axis test before returning to full production.
Compatible Replacement Models
| Model | Tier | Notes |
|---|---|---|
| NYM04.1-MCUETHER-NY4112 (same suffix) | ✅ Drop-in Replacement | 100% match. Confirm MNR and firmware against the old card. |
| NYM04.1-MCU-ETHER-NY4114 / NY4110 | ⚠️ Software Compatible | Same family, different variant. Requires parameter reload and OEM confirmation — budget 4–8 hours. |
| Rexroth IndraDrive / newer motion platform | ❌ Hardware Mod Required | New cabinet, rewiring, re-commissioning. Justified only during a full machine upgrade. |
Frequently Asked Questions
Is this actually in stock, or do you source after I order?
Straight answer: legacy NY-series spares move fast. I confirm physical inventory and send photos of the actual label before quoting a lead time. If it needs sourcing, I say so upfront.Can I hot-swap this safely?
No. It’s a control card in a live motion path. Pulling it under load can fault the axes and damage the fieldbus connection. Safe state, de-energize, discharge, then swap.The suffix on my old card is different from the listing. Does it matter?
Yes, enormously. NY4110, NY4112, and NY4114 are different variants. Send me a photo of your old card’s label and I’ll confirm before shipping.Do I need to reload parameters after replacement?
Almost certainly. The card holds motion profiles and fieldbus configuration. Back up the old parameter set before removal — rebuilding by hand takes hours.Will my PLC program be lost during replacement?
The MCU doesn’t hold the main PLC logic, so a normal swap won’t erase it. Still, back up everything first. I’ve seen too many people back up after the fact.Do you offer a warranty?
12 months on non-human-caused failure. Wrong suffix shipped by me — that’s on me. Installed without verifying the label — that’s not covered.