Key Technical Specifications
| Parameter | Typical / Verified Value |
|---|---|
| Full part number | MCGG22D1CB0753C |
| Manufacturer | GEC ALSTHOM / ALSTHOM |
| Product type | Overcurrent & earth-fault protection relay (MCGG22 family) |
| Protection functions | 50/51 OC, 50N/51N EF; IDMT + definite-time |
| CT inputs | Typically 1 A / 5 A, phase and earth |
| Auxiliary supply | Typically 110–250 V DC (build-dependent) |
| Trip outputs | Form-C relay contacts for trip/alarm |
| Communication | Usually none on base MCGG22 variants |
| Operating temperature | Typically −10 °C to +55 °C |
| Mounting | Draw-out case, panel/flush mount |
| HS Code | 8536.49.00 |
| Final specs | Confirm with OEM datasheet and physical label |
Product Introduction
Legacy switchgear does not forgive guesswork. When a feeder relay starts drifting or its contacts stick, you do not want a procurement debate; you want the correct draw-out unit already tested and ready to slide in. The ALSTHOM MCGG22D1CB0753C sits in that older but still common GEC ALSTHOM protection layer, usually protecting feeders, motors, or distribution circuits where IDMT overcurrent and earth-fault functions are enough.Engineers keep these relays around because they are simple, mechanically robust, and easy to test with a plug-in test block. The MCGG22 family typically offers phase and earth IDMT curves plus high-set stages, 1 A / 5 A CT compatibility, and changeover trip/alarm contacts. That is not fancy, but it is predictable. The “D1CB0753C” suffix is the tricky part: it encodes build options, so always match the nameplate before you commit.
Quality SOP & Tech Pitfalls
The Lab Report (SOP)
- Visual inspection: check case cracks, terminal corrosion, missing seals, and nameplate legibility.
- Nameplate verification: confirm MCGG22D1CB0753C, build code, CT ratio markings, and auxiliary voltage.
- Mechanical check: verify draw-out mechanism, test-plug pins, and contact cleanliness.
- Insulation resistance test between CT circuits, auxiliary supply, and case.
- Secondary injection test: verify pickup, timing, IDMT curve behavior, and high-set operation.
- Output contact check: confirm trip/alarm contact operation and contact resistance.
- Anti-static packing, photo record, and test sheet before dispatch.
The Engineer’s Warning (Pitfalls)The most common failure mode is not the relay itself; it is ordering the wrong suffix. MCGG22 variants can differ in CT rating, auxiliary voltage, curve set, and output configuration. I have seen a crew swap a relay that physically fit but had the wrong auxiliary range, and the unit either chattered or failed to pick up during testing. Also, never ignore the test plug. Bent pins or oxidized contacts will make a perfectly good relay look dead.
Installation & Configuration Guide
- Pre-Installation
- Isolate the feeder and apply proper LOTO.
- Verify CT secondary circuits are shorted before disconnecting.
- Photograph the existing relay settings, curve selectors, taps, and wiring.
- ⚠️ Do not open CT secondaries under load.
- Removal
- Insert the test plug if available to maintain circuit integrity.
- Release the draw-out locking mechanism.
- Withdraw the relay carefully and label all external connections.
- Installation
- Copy all selector switches, taps, TMS, pickup, and high-set settings from the old relay.
- Inspect the case contacts and test-plug pins.
- Seat the relay fully and confirm mechanical locking.
- Power-On & Testing
- Verify auxiliary voltage matches the nameplate.
- Perform secondary injection on phase and earth elements.
- Confirm trip/alarm outputs and breaker interlocks.
- Record final settings and return the relay to service only after acceptance testing.
Compatible Replacement Models
| Compatibility | Candidate | Notes |
|---|---|---|
| ✅ Drop-in | ALSTHOM MCGG22 with identical suffix D1CB0753C | Best path; confirm CT ratio, aux supply, and curve set |
| ⚠️ Verify before use | Other MCGG22 variants (e.g., MCGG22L1CB0753E) | Same family but different options; settings and wiring may differ |
| ⚠️ Engineered replacement | ALSTHOM MiCOM feeder relay with matching CT/aux/IO | Requires setting translation, wiring check, and possibly new test plug |
| ❌ Not recommended | Unverified MCGG42/52/62/82 variants | Contact layout and functions may not match |
Frequently Asked Questions (FAQ)
Is MCGG22D1CB0753C still in production?
Unlikely. This is a legacy GEC ALSTHOM relay. Most units now come from surplus stock or existing plant spares.Can I replace it with any MCGG22 relay?
No. The suffix matters. CT rating, auxiliary voltage, curve selection, and output configuration must match.Does it support communication?
Base MCGG22 relays typically do not include serial communication. Some later ALSTHOM/MiCOM variants do, but that is a different upgrade path.Can I test it without removing the relay?
Often yes, using the test plug and secondary injection. That is one reason these draw-out relays aged well in substations.What auxiliary voltage does it need?
Common MCGG builds use a DC auxiliary supply in the 110–250 V DC range, but you must confirm this on the nameplate for MCGG22D1CB0753C.Is it safe to hot-swap?
No. Treat it as a de-energized replacement unless your switching procedure and protection scheme explicitly allow live testing with a test block.What warranty should I expect?
A responsible surplus supplier should offer at least a 12-month warranty plus a test report. For legacy relays, documentation is as important as the hardware.