Key Technical Specifications
| Parameter | Specification |
|---|---|
| Product family | Honeywell LG1093 series UV flame detector |
| Cross-reference | 261A1812P012 listed as cross-reference to LG1093AA24 |
| Detection principle | Ultraviolet flame detection for hydrocarbon combustion |
| Housing material | Stainless steel body with fused quartz viewing window |
| Cable | PTFE cable |
| Supply voltage | DC supply variant |
| Process environment | High-temperature and high-pressure burner environments; exact limits vary by revision |
| Mounting | Direct burner or furnace mounting with appropriate cooling/purge arrangement |
| Typical applications | Industrial boilers, process heaters, gas turbines, incinerators, and burner management systems |
| Condition | New surplus / inventory stock; verify nameplate and cable configuration |
Product Introduction
LG1093AA24 is a Honeywell ultraviolet flame detector commonly used in industrial burner management systems. It does not control the burner by itself; it senses whether a flame is present and reports that condition to the flame safeguard relay or burner controller. The 261A1812P012 number is typically encountered as a cross-reference or alternate part identifier associated with LG1093AA24.This type of detector is designed for harsh combustion environments. The stainless steel housing and fused quartz window allow it to survive near-burner heat and pressure, while the PTFE cable protects the signal lead from thermal and chemical stress. It is commonly found on boilers, process heaters, incinerators, and gas turbine auxiliary systems where reliable flame proving is critical.The main field risk is treating LG1093AA24 and 261A1812P012 as automatically identical without checking the nameplate. Electrical supply, cable length, connector type, and process rating can vary between revisions. If the detector is being replaced in an existing burner system, the safest approach is to match the original part number, cable length, voltage rating, and mechanical mounting.
Quality SOP & Tech Pitfalls
The Lab Report (SOP)
- Visual inspection: verify Honeywell branding, LG1093AA24 / 261A1812P012 label, serial number, and cable condition.
- Window inspection: check the fused quartz window for cracks, coating, carbon deposits, or thermal damage.
- Cable integrity check: inspect PTFE cable for cuts, abrasion, heat damage, and connector seating.
- Electrical check: verify supply voltage compatibility and insulation resistance per site procedures.
- Functional test: test with a compatible flame amplifier or burner controller using a safe UV test source where permitted.
- Final packing: moisture protection, reinforced carton, and photos of nameplate, cable, and test results.
The Engineer’s Warning (Pitfalls)
- Cross-reference mismatch. 261A1812P012 and LG1093AA24 are commonly linked, but electrical and mechanical details must still be confirmed.
- Wrong supply voltage. UV detectors may have different supply requirements; installing the wrong variant can prevent flame proving.
- Window contamination. A dirty or cracked quartz window can cause false flame loss or nuisance trips.
- Cable routing errors. Flame detector cables should be routed away from ignition transformers and high-noise power conductors to avoid false signals.
Installation & Configuration Guide
- Pre-Installation: ️ Place the burner in safe shutdown and follow site lockout/tagout procedures. Confirm the replacement detector matches the original model, cable length, and supply voltage.
- Removal: Photograph the existing mounting position, cooling/purge connections, cable routing, and amplifier/controller wiring.
- Installation: Mount the detector securely with the correct gasket or fitting. Ensure the quartz window is clean and properly oriented toward the flame zone. Reconnect the cable and verify polarity/supply rating.
- Commissioning: Verify flame amplifier compatibility. Check flame signal during purge, ignition, and run conditions. Confirm flame failure response and safe shutdown before returning the burner to automatic operation.
Compatible Replacement Models
- Drop-in Replacement: Honeywell LG1093AA24 with matching cable length, supply voltage, and mounting configuration.
- ️ Cross-Reference Replacement: 261A1812P012 or other LG1093 series UV detectors. Compatibility must be confirmed against the original nameplate and burner controller.
- Non-Compatible Substitutes: IR flame detectors, ionization probes, or generic UV sensors should not be used without verifying amplifier compatibility and burner safety logic.
Frequently Asked Questions (FAQ)
Q: Are LG1093AA24 and 261A1812P012 the same part?
They are commonly listed as cross-references, but the exact electrical rating, cable length, and revision should be confirmed on the nameplate.Q: What does this detector do?
It detects UV radiation from a hydrocarbon flame and reports flame presence to the burner safeguard controller.Q: Can it work with any Honeywell controller?
Not automatically. It must be compatible with the flame amplifier or burner relay used in the system.Q: Is it still in production?
It is generally treated as a legacy industrial part. Most available units are surplus or inventory stock.Q: What should I check before ordering?
Model number, cross-reference status, supply voltage, cable length, window condition, mounting thread, and amplifier compatibility.