Key Technical Specifications
| Parameter | Specification |
|---|---|
| Product Model | PFTL301E |
| Manufacturer | ABB |
| Product Type | Pressductor horizontal pillowblock load cell |
| Measuring Direction | Horizontal web tension force only |
| Typical Rated Capacities | Multiple kN variants |
| Overload Capacity | High overload tolerance in measurement direction |
| Accuracy Class | Series-level accuracy class |
| Repeatability Error | Low repeatability error |
| Deflection | Low deflection depending on capacity |
| Technology | Magnetoelastic Pressductor; no strain gauges |
| Output Signal | Low-impedance AC coil signal to ABB tension electronics |
| Mounting | Pillowblock / bearing housing mount at measuring roll |
| Typical Pairing Electronics | PFEA111, PFEA112, PFEA113 |
| Environment | Sealed stainless construction; suitable for industrial web lines |
Product Introduction
The ABB PFTL301E is a horizontal web-tension load cell built around ABB’s Pressductor magnetoelastic technology. Unlike vertical load cells, it does not carry roll weight. It only senses the horizontal force created by web tension, so it can be sized to the actual tension range rather than the total roll load.That matters on lines where the roll is heavy but the required tension is light. A strain-gauge cell sized for roll weight may spend most of its life near the bottom of its range. The PFTL301E avoids that problem because the vertical load is mechanically separated from the measurement axis. The result is better signal resolution, less drift, and more stable tension control during acceleration, deceleration and web threading.Because it uses magnetoelastic measurement instead of strain gauges, there are no fragile foil elements to creep, drift or fail under repeated overload. The cell produces a robust low-impedance AC signal that is naturally resistant to electrical noise and ground faults. It must be connected to an ABB tension controller or signal conditioner, which then provides the usable analog or fieldbus output.
Quality SOP & Tech Pitfalls
The Lab Report (SOP)
- Nameplate verification: confirm model PFTL301E, rated capacity, order code and serial number.
- Mechanical inspection: check housing, bearing seats, cable entry and mounting surfaces for damage.
- Coil resistance check: measure coil circuits against expected values to detect opens, shorts or moisture ingress.
- Insulation check: verify coil-to-body insulation before installation.
- Electronics pairing test: connect to compatible ABB tension electronics and verify stable zero, response to applied force and absence of erratic drift.
- Cable and connector check: inspect for cracked insulation, broken strain relief or corroded pins.
- Final packing: protect mounting faces, seal cable ends, and ship in rigid packaging.
The Engineer’s Warning (Pitfalls)
- Do not confuse PFTL301E with PFCL301E. PFTL301E measures horizontal tension force; PFCL301E measures vertical force. Installing the wrong type will produce incorrect tension readings.
- It is not a standalone transmitter. The PFTL301E cannot output 4–20 mA, 0–10 V or fieldbus signals without ABB tension electronics.
- Rated capacity must match the original. Cells with different kN ratings cannot be substituted without revalidation.
- Cable routing matters. Poor shielding, broken cable glands or moisture in the connector can mimic sensor failure.
- Do not recalibrate aggressively to hide mechanical problems. Misaligned rolls, bad bearings, incorrect wrap angle or damaged adapter plates will corrupt tension measurement regardless of electronics settings.
Installation & Configuration Guide
- Pre-Installation
- Isolate the measuring roll and secure the web.
- Record the existing cell rating, orientation, cable route and electronics settings.
- Verify the replacement PFTL301E capacity matches the original.
- Removal
- Disconnect the cable at the electronics side first.
- Remove bearing housing or adapter plate as required.
- Extract the load cell without striking the housing or cable entry.
- Installation
- Confirm the cell is mounted to measure horizontal tension force.
- Ensure bearing seats and adapter plates are clean and undamaged.
- Route the cable away from heat, moving parts and high-noise power cables.
- Commissioning
- Connect to the correct ABB tension electronics channel.
- Verify zero stability after mechanical installation.
- Perform tension verification with known web load or calibrated test procedure.
- Recheck zero after the first production run.
Compatible Replacement Models
| Model | Compatibility | Notes |
|---|---|---|
| ABB PFTL301E, same capacity | Drop-in replacement | Preferred option when rating and mounting match. |
| ABB PFTL301E, different capacity | Review required | Requires electronics reconfiguration and process validation. |
| ABB PFCL301E | Not a direct substitute | Vertical force cell; different measurement axis. |
| Non-ABB strain-gauge cells | System redesign required | Different signal, mounting and calibration behavior. |
Frequently Asked Questions (FAQ)
What does the PFTL301E measure?
It measures horizontal web tension force at a measuring roll using ABB’s Pressductor magnetoelastic technology.Can it measure roll weight?
No. That is the PFCL301E’s role. The PFTL301E is designed to ignore vertical roll weight and respond to horizontal tension force.Does it output 4–20 mA?
Not directly. It outputs a low-impedance AC coil signal. A matched ABB tension controller such as PFEA111/PFEA112/PFEA113 is required for analog or fieldbus outputs.Can I replace a PFCL301E with a PFTL301E?
No. They measure different force directions. Substitution would require mechanical and control-system redesign.Is recalibration required?
Pressductor cells are inherently stable and typically do not drift like strain-gauge sensors, but system verification is still required after replacement.What should I check before ordering?