Key Technical Specifications
| Parameter | Value |
|---|---|
| Ethernet processor speed | 200 MHz |
| Ethernet ports | Two, 10BaseT / 100BaseTX, auto-sensing shielded RJ-45 |
| IP addresses | One (plus configurable redundant IP) |
| Embedded Ethernet switch | Yes — allows daisy-chaining of Ethernet nodes |
| Station Manager port | RS-232 DCE, 9-pin female D-sub, 1200–115,200 bps |
| LAN standards | IEEE 802.2 LLC Class I; IEEE 802.3 CSMA/CD 10/100 Mbps |
| Protocols | SRTP (server/client), Modbus TCP server & client, EGD producer/consumer |
| Time sync | SNTP client (requires CPU firmware 5.00 or later) |
| Hot swap | Supported; firmware 2.51 or later required to enable |
| Compatible backplanes | IC695CHS007, CHS012, CHS016 |
| Slot count | One |
| Status LEDs | Ethernet OK, LAN OK, log clear, per-port activity and speed |
Product Introduction
Every plant I’ve walked into with an RX3i rack has one of these, and it’s usually the module nobody wants to touch. The IC695ETM001 is GE’s Ethernet interface for the RX3i platform — a single-slot card that carries SRTP, EGD, and Modbus TCP traffic over two auto-sensing 10/100 Mbps ports. It’s the bridge between an RX3i CPU and everything older in the building: Series 90-30, VersaMax, third-party SCADA.Engineers pick it because it does three jobs in one slot. The embedded switch lets you daisy-chain nodes instead of buying an external switch per panel. The redundant IP option lets two controllers in a hot-standby pair share one address, which saves you from rewriting application logic during failover testing. And the dedicated RS-232 Station Manager port gives you a serial back door when the network is the thing that’s broken. This particular revision is picky about firmware pairing with the CPU — mismatched versions will let the module power up happily and then refuse to pass EGD data. Verify both versions before you call it a good unit.
Quality SOP & Tech Pitfalls
The Lab Report (SOP)
- Visual / counterfeit check — nameplate legibility, catalog number, revision suffix, mold quality, solder joints on the RJ-45 shell.
- Live test on a test rack — installed in a known-good RX3i backplane, powered, boot sequence watched.
- Multimeter / insulation checks — Fluke 115 on the 24 V DC feed and shield continuity to the RJ-45 shell.
- Link and traffic test — both ports pinged, SRTP channel opened, EGD exchange verified against a peer.
- Firmware version logged — recorded on the test certificate, not just eyeballed.
- Anti-static sealing — ESD strap throughout, anti-static bag, foam-form carton, dust plugs in the RJ-45 ports.
The Engineer’s Warning (Pitfalls)Firmware mismatch is the number one killer. I’ve seen a perfectly good replacement module sit in a rack for three weeks while a junior tech chased a “bad network cable,” because the incoming card ran older firmware than the CPU expected. The module lit up. The LEDs looked right. EGD just didn’t exchange.Second: photograph everything before you pull the old card. MAC address label, serial number label, IP configuration, and the exact slot position. This module has no DIP switches, so the failure mode isn’t a lost jumper — it’s a lost IP address.
Installation & Configuration Guide
Phase 1 — Pre-Installation (⚠️)
- ⚠️ Put the CPU into STOP mode, or confirm your plant’s hot-swap procedure is authorized.
- ⚠️ Wait for stored energy to discharge — 30 seconds minimum on the 24 V DC bus.
- ⚠️ Photograph the old module’s nameplate, IP configuration screen, and slot position.
- Record the existing firmware version from the Station Manager before removal.
Phase 2 — Removal
- Label both Ethernet cables at the connector, not the jacket.
- Release the DIN-rail or backplane retaining clips with a flat screwdriver — pull straight out, never lever against the neighboring module.
- Bag the old card with its MAC label visible.
Phase 3 — Installation
- Copy the IP address, subnet, and redundant IP settings from your photo — this single step prevents roughly 90% of startup failures.
- Seat the module firmly into the slot until the retaining clip engages. Do not force a misaligned card.
- Reconnect the labeled Ethernet cables to the correct ports.
Phase 4 — Power-On & Testing
- Confirm 24 V DC at the backplane before inserting the card.
- Watch the boot sequence: Ethernet OK, then LAN OK. If LAN OK doesn’t set, treat every other status bit as invalid.
- Ping the module, then verify an SRTP channel and an EGD exchange.
- Download and verify the application program. Confirm firmware versions match the CPU.
Compatible Replacement Models
| Tier | Model | Notes |
|---|---|---|
| ✅ Drop-in | IC695ETM001 (base catalog) | Same hardware; confirm revision suffix and firmware compatibility |
| ✅ Drop-in | IC695ETM001-HV / -HT | Sibling revisions; verify nameplate against the original |
| ⚠️ Software Compatible | IC695ETM001CA | Conformal-coated variant; same function, different environmental rating |
| ⚠️ Software Compatible | IC695NIU001 | Network Interface Unit; different role, needs reconfiguration |
| ❌ Hardware Mod Required | IC693CMM321 | Series 90-30 Ethernet interface; wrong platform, do not substitute |
Frequently Asked Questions (FAQ)
Can I hot-swap this safely?
Yes, but only with firmware 2.51 or later installed. Without that version, hot insertion is unsupported and you’re gambling on the backplane. If you’re not certain what firmware is loaded, stop the CPU.Is the -EK revision different from the base part?
Possibly. Suffixes on this catalog typically denote option or environmental variants. Compare the nameplate against your old card and check GFK-2332W. Don’t assume.Can I run it at 1 Gbps?
No. It’s 10/100 Mbps with auto-negotiation, full stop. If your network is gigabit, the port will drop to 100 Mbps.Why won’t my new module pass EGD data?
Nine times out of ten it’s a firmware mismatch with the CPU, not a cable. Check both versions in the Station Manager before you blame the switch.Do I need an external transceiver?
No. The RJ-45 ports connect directly to a 10BaseT or 100BaseTX network. That’s a change from the older Series 90-30 Ethernet interface, which did require one.Is it really in stock?
On a legacy platform, “in stock” usually means someone somewhere has one. Ask for the physical location and a nameplate photo before you commit.What’s the warranty?
One year on new surplus units is the channel standard. Get it in writing — and ask whether it covers firmware-related incompatibility.