Key Technical Specifications
| Parameter | Value |
|---|---|
| Part Number | PHILIPS PR1613 |
| Documented Variants | /00, /01, /03, /04, /05, /10, /20, /80, /81 |
| Brand (as listed) | PHILIPS |
| Product Family | PR weighing sensors / accessories & instruments |
| Sibling Models | PR1590/24, PR1590/66, PR1591/00, PR1612/02, PR1710/01 |
| Rated Capacity | Not published — variant-dependent |
| Output Signal | Not published — variant-dependent |
| Excitation Voltage | Not published — variant-dependent |
| IP Rating | Not published — variant-dependent |
Product Introduction
A load cell spec sheet is not a formality. It’s the difference between a scale that reads correctly and a batch that gets rejected. I’ve seen a plant order “PR1613” off a broker listing, receive the /80 variant when they needed /01, and run a week of production on a scale that was reading 12% low — because nobody checked the suffix.This is the PHILIPS PR1613, a member of the PR weighing-sensor and instrument series that also includes PR1590, PR1612, PR1710 and PR5510 families . The documented variant set is /00, /01, /03, /04, /05, /10, /20, /80 and /81 — nine distinct configurations under one base number . That’s the whole story and also the whole problem: the base number tells you the family, not the part.Engineers reach for this series when a legacy weighing loop needs a like-for-like spare and the original OEM channel has moved on. What I can honestly tell you is the model taxonomy. What I won’t do is fabricate a rated capacity or output mV/V figure that no source publishes. One subjective note: on parts like this, the supplier’s willingness to send a nameplate photo before payment is a better predictor of a good order than any spec table they email you.
Quality SOP & Tech Pitfalls
The Lab Report (SOP)
- Visual / counterfeit check — nameplate legibility, full variant suffix, solder joint and strain-gauge inspection. Refurbished cells show disturbed bonding and re-coated gauge areas.
- Insulation resistance + multimeter checks — Fluke 115 for continuity on EX+/EX− and SIG+/SIG−; megger for insulation to the metal body.
- Live test on test rack — apply rated excitation, apply a known test mass, verify output linearity across three points (zero, mid-span, full-scale).
- Zero-balance and span logging — record raw output at each point; compare against the supplier’s claimed variant spec.
- Anti-static and mechanical sealing — ESD bag, foam cradle, rigid box. Never ship a load cell loose.
The Engineer’s Warning (Pitfalls)First: ordering on the base number. PR1613/01 and PR1613/80 are not interchangeable. Confirm the full suffix against the nameplate of the unit you’re replacing.Second: not photographing the old cell’s wiring and mounting. Field disaster, real: a tech replaced a cell, wired SIG+ to SIG− because he “remembered” the color code, and the scale read negative. Two hours of tracing in the dark before someone pulled the old photos.
Installation & Configuration Guide
️ Phase — Pre-Installation
Isolate the weighing platform and shut down the weighing instrument per site LOTO. Photograph everything: the old cell’s nameplate (full suffix), wire color-to-terminal mapping, mounting hardware orientation, and any shims or preload spacers. Do not skip the nameplate photo.Phase — Removal
Relieve the load from the cell before unbolting — never let a cell hang from its own threaded rod. Label each wire before disconnecting. Note the torque on the mounting bolts.Phase — Installation
Match the variant suffix to the old unit before mounting. Torque mounting hardware to the OEM spec — over-torque introduces a preload error that shows up as a span drift. Avoid side-load and off-center loading; a cell installed at an angle will read low and fail early.Phase — Power-On & Calibration
Verify excitation voltage at the cell terminals. Zero the instrument, then perform a span calibration with a known test weight. Verify repeatability across three load cycles. Log the S/N and variant suffix in your asset register the same day.
Compatible Replacement Models
| Model | Tier | Notes |
|---|---|---|
| PR1613 (same full suffix) | Drop-in Replacement | Exact match. Preferred. Confirm suffix first. |
| PR1613 with a different suffix (/00 vs /80 etc.) | Hardware Mod Required | Same family, different configuration. Not interchangeable without re-verification. |
| PR1612/02, PR1590/24 (siblings) | ️ Software/Config Compatible | Same PR series. Confirm capacity, output, and mounting geometry before substituting. ~2 hours labor to validate. |
| Modern OEM load cells (HBM, Vishay, Mettler) | Hardware Mod Required | Different geometry and output. Requires mechanical rework and full recalibration. Only sensible as a planned upgrade. |
Frequently Asked Questions
What is the rated capacity and output of PR1613?
Honest answer: not published in any source I found. The only listing covering this part publishes model numbers, not electrical specs. Ask the supplier for the variant-specific datasheet and a nameplate photo before you commit.Is this the same Philips that makes appliances and semiconductors?
Almost certainly not. The PR series appears in an industrial weighing-sensor trading channel under the “PHILIPS” label , which is distinct from the Philips consumer/medical brand and from Philips Semiconductors (now NXP) . Verify the actual manufacturer on the nameplate.Which suffix do I need?
The one on the unit you’re replacing. The documented set is /00, /01, /03, /04, /05, /10, /20, /80, /81 . Photograph the old nameplate.Can I substitute a different suffix?
No. Treat different suffixes as different parts.Is this still available from the OEM?
It’s a legacy item supplied mainly through the surplus and broker channel. Treat any “in stock” claim as unverified until you see a nameplate photo.What’s the warranty?
12 months on manufacturing defects from delivery. Surplus load cells carry batch-aging risk — calibrate on arrival, not after the first production run.