Description
Key Technical Specifications
| Parameter | Value |
|---|---|
| Product Model | MVAJ13D1GB0780A |
| Manufacturer | GEC ALSTHOM / ALSTHOM |
| Product Type | Low-burden tripping relay |
| Series Family | MVAJ tripping relay series |
| Primary Application | Protection relay output, trip signaling, auxiliary control |
| Coil Voltage | Not universally published for this suffix; verify on nameplate |
| Contact Configuration | Typically relay output; exact form depends on version |
| Contact Rating | Not confirmed for this exact suffix; check OEM label |
| Mounting | Panel or DIN-rail style depending on variant |
| Supply Type | AC or DC coil possible; must confirm per unit |
| Condition | New surplus / Refurbished tested / Used |
| Warranty | 12 months |
Product Introduction
GEC ALSTHOM MVAJ13D1GB0780A is a low-burden tripping relay used in legacy protection and control panels. It sits downstream of protection relays and converts a protection command into a reliable trip or auxiliary switching signal.Its main value is compatibility with older switchgear, generator protection, transformer protection, and feeder relay panels. The “low-burden” designation means the coil draws less current from the protection relay output, which helps avoid loading issues on older CT/VT or auxiliary circuits. Exact coil voltage, contact rating, and mounting style must be confirmed from the physical nameplate before installation.
Installation & Configuration Guide
Preparation (10 min)
- Photograph the original relay nameplate, terminal labels, and wiring.
- Confirm coil voltage, contact arrangement, and mounting type.
- Verify system control voltage is within ±10% of the relay rating.
- Prepare insulated tools, terminal labels, and ESD-safe handling.
Removal (5–10 min)
- De-energize the control circuit where possible.
- Mark each wire before removal.
- Remove terminal screws or plug connector carefully.
- Do not force the relay if it is panel-locked or socket-mounted.
Installation (10 min)
- Confirm the new unit matches the original mounting footprint.
- Install the relay and verify mechanical retention.
- Reconnect terminals using the marked wiring list.
- Double-check polarity if the coil is DC.
Power-On & Test (10 min)
- Measure coil supply voltage before energizing.
- Apply control voltage and observe relay operation.
- Verify contact closure/opening with a multimeter.
- Confirm trip signaling reaches the downstream breaker or auxiliary circuit.
- Record coil voltage, contact response, and nameplate data.
Troubleshooting Quick Reference
| Symptom | Likely Cause | First Check |
|---|---|---|
| Relay does not pick up | Wrong coil voltage | Compare nameplate vs. measured supply |
| Weak or inconsistent operation | Low control voltage | Measure voltage at relay terminals under load |
| Contacts do not switch | Wiring error | Verify COM/NO/NC against original labels |
| Relay chatters | AC ripple or loose terminal | Tighten terminals; check DC supply ripple |
| Overheating coil | Continuous overvoltage | Measure sustained coil voltage |
| Intermittent trip signal | Oxidized contacts or loose wiring | Inspect terminals; perform contact continuity test |
Dimensions, Mounting & Wiring Notes
- Dimensions: Not standardized across all MVAJ suffixes; measure H × W × D from the original unit.
- Mounting: May be panel-mounted, socket-mounted, or DIN-rail compatible depending on version.
- Terminal Notes: Label every wire before removal. Some versions use screw terminals; others use plug-in bases.
- Wiring Caution: Do not assume coil polarity or contact mapping. Verify against the original relay and OEM documentation.
FAQ
Is MVAJ13D1GB0780A still available new?
Not as regular OEM stock. Units are typically new surplus, refurbished tested, or used. Condition is confirmed per batch.Can I replace it with any MVAJ relay?
No. The suffix matters. Coil voltage, contact form, mounting, and terminal layout may differ. Always match the nameplate.What systems use this relay?
It commonly appears in legacy protection panels, switchgear trip circuits, generator/transformer protection schemes, and auxiliary control circuits.I only have the part number — is that enough to order?
Not reliably. Send a nameplate photo, terminal photo, coil voltage, and mounting style before purchase.Do you test it before shipping?
Yes. Each unit undergoes visual inspection, nameplate verification, coil energization, contact continuity check, and terminal confirmation. Function is verified under test conditions.What is the lead time?
If in stock, shipment can usually be arranged within 1–3 business days. Non-stock items require separate confirmation.Is there a modern replacement?
Possible, but only after reviewing coil voltage, contact rating, burden, mounting, and panel wiring. A direct drop-in replacement is not guaranteed.