Description
Key Technical Specifications
| Parameter | Specification |
|---|---|
| Manufacturer | Bosch Rexroth |
| Series | IndraDyn S MHD |
| Motor Type | AC Synchronous Servo Motor |
| Frame Size | MHD 115 |
| Variant Code | C |
| Speed Code | 024 |
| Encoder / Feedback | PG1 |
| Brake / Flange Code | BN |
| Typical Drive Family | IndraDrive Mi / IndraDrive Cs / IndraDrive M |
| Feedback Interface | Rexroth digital encoder interface |
| Holding Brake | Yes, indicated by BN suffix |
| Connector Orientation | Typically rotatable on MHD series |
| Typical Applications | Packaging, robotics, machine tools, material handling |
| Compliance | CE / UL per nameplate |
Product Introduction
The MHD115C-024-PG1-BN sits in the IndraDyn S family, where Rexroth balanced compact frame size with strong dynamic performance. The MHD series is widely used when a machine needs fast acceleration, tight position control, and a motor that still fits into a confined mounting space. The 115 frame places it above the smaller MHD071 and MHD090 units, so it is typically selected for mid-range axes rather than light-duty positioning.The “024” speed code signals a high-speed winding, which is common in packaging, indexing, and spindle-adjacent applications. The PG1 feedback option provides the encoder data the drive needs for commutation and closed-loop control. The BN suffix normally indicates a holding brake and a specific flange/connector arrangement, which matters during replacement because brake voltage, connector orientation, and cable pinout must match the original installation.From a maintenance perspective, this motor is straightforward as long as the drive project is intact. If the IndraDrive still has the correct motor data set, encoder parameters, and brake configuration, a like-for-like swap is usually fast. If the project is missing, you will need to rebuild the motor data from the nameplate or Rexroth documentation before commissioning.
Quality SOP & Tech Pitfalls
The Lab Report (SOP)Each unit is checked before dispatch:
- Nameplate verification — model, serial number, encoder code, brake code, and manufacturing data.
- Mechanical inspection — shaft runout, flange surface, keyway, mounting holes, and connector condition.
- Insulation resistance test — winding-to-ground check with a handheld tester.
- Winding resistance check — phase-to-phase balance verification.
- Brake function test — verify brake release and engagement if equipped.
- Encoder feedback check — confirm signal presence and plausibility when rotated.
- Rotation test — smooth manual rotation, no grinding or abnormal noise.
- Anti-static packaging, seal, and test report. Video available on request.
The Engineer’s Warning (Pitfalls)First, do not substitute based on frame size alone. Another MHD115 motor may share the same mechanical dimensions but have different winding, encoder, or brake data. Feeding incorrect motor data into an IndraDrive can cause overcurrent faults, poor tuning, or brake timing issues.Second, verify the encoder type. Rexroth used several feedback options across the MHD family. A PG1 motor is not automatically interchangeable with an NG0, PG0, or other feedback variant without drive reconfiguration.Third, check the brake circuit. Holding brakes are safety-relevant in vertical axes and indexing applications. Confirm brake voltage, wiring, and release timing before putting the machine back into production.
Installation & Configuration Guide
1. Pre-Installation ⚠️
- Lock out power to the IndraDrive and motor.
- Record the original nameplate data and cable connections.
- Confirm the drive project contains the correct motor data set.
- Verify brake supply voltage and wiring.
2. Removal
- Disconnect power, brake, and encoder cables.
- Support the motor before removing mounting bolts.
- Protect the shaft and encoder from impact.
- Inspect cables and connectors for damage.
3. Installation
- Mount the replacement MHD115C-024-PG1-BN using the original bolt pattern.
- Align the coupling or mechanical load carefully.
- Reconnect power, brake, and encoder cables.
- Ensure connector orientation matches the original layout.
4. Commissioning
- Verify insulation and wiring before energizing.
- Load the correct motor data set in the IndraDrive.
- Confirm encoder feedback is recognized.
- Test brake release and engagement if applicable.
- Run low-speed jog, then verify tuning, current balance, and temperature.
Compatible Replacement Models
| Compatibility | Model | Notes |
|---|---|---|
| ✅ Drop-in Replacement | MHD115C-024-PG1-BN | Same ordering code. Preferred replacement. Verify nameplate and project data. |
| ⚠️ Possible Alternative | MHD115C-024 with different suffix | May work if encoder, brake, flange, and drive data match. Requires engineering verification. |
| ⚠️ Series Alternative | Other IndraDyn S MHD115 variants | Same family, but winding and feedback may differ. Not automatic drop-in. |
| ❌ Not Directly Compatible | MKD / MAD / MSK series | Different mechanical and electrical data. Requires drive reconfiguration and mechanical validation. |
| ❌ Not Compatible | Non-Rexroth servo motors | Different feedback, connector, and drive integration. Cannot be treated as direct replacement. |
Frequently Asked Questions (FAQ)
Q: What does MHD115C-024-PG1-BN mean?
It identifies an IndraDyn S MHD servo motor, 115 frame, C variant, 024 speed code, PG1 encoder option, and BN brake/flange configuration. The exact electrical data must be confirmed from the nameplate.Q: Can I replace it with another MHD115 motor?
Only if the encoder, brake, winding, shaft, flange, and drive data match. Rexroth suffix codes are not cosmetic; they change how the drive commutates and controls the motor.Q: Which drive does it work with?
It is designed for Bosch Rexroth IndraDrive families. Compatibility depends on the drive firmware, motor data set, and encoder interface.Q: Is this motor discontinued?
The MHD series is a mature product line. Some variants remain available through surplus or tested stock channels. Availability should be checked against the exact ordering code.Q: Can I run it without the brake connected?
Not if the application relies on the holding brake for safety or load retention. The brake must be wired and configured correctly before commissioning.Q: What happens if the encoder data is wrong?
The drive may fault, run rough, overheat, or fail to commutate properly. Encoder configuration must match the motor feedback type.Q: Do you provide test reports?
Yes. Each unit can be supplied with an inspection and test report. Additional bench testing can be arranged on request.




Tel:
Email:
WhatsApp: 